6840 S. Tucson Blvd, Tucson, AZ 85756, U.S.A.
GET A CONSULTATION

SEAWALLS, BEAMS & SLABS

SPiRe®+: Stay-in-Place FRP Panels for Seawalls, Beams & Slabs

Pultruded FRP panels that do three jobs at once: formwork, reinforcement and a waterproof barrier. Bolted in front of a seawall, beam or slab and filled with grout, they form a new structural face, even underwater and without cofferdams.

  • Installs underwater without cofferdams
  • Virtually no surface preparation
  • Replaces formwork, rebar and waterproofing
Crew repairing a corroded seawall with FRP panels
3-in-1 formwork, reinforcement and waterproofing
(914 mm) wide pultruded FRP panels
3 ft
lengths in 2 ft increments, longer on special order
6 to 20 ft
(5 mm) wall, 3.57 lb/ft² (17.42 kg/m²)
0.20 in.
Grade 60 rebar equivalency per the data sheet
No. 6 @ 3.5 in.

HOW THE PANEL WORKS

Formwork, Rebar and Waterproofing in One Panel

SPiRe®+ panels are made at the QuakeWrap® facility by pultrusion: glass fibers are saturated with vinyl ester resin and formed into rigid panels with uniform geometry and thickness. The outside face is flat and smooth. The inside face has protruding T profiles and a grit coating.

The grit-coated face bonds to grout and concrete, and the T profiles lock into it, so the flat panel and the T profiles act together as the tension reinforcement of the repaired wall, beam or slab. In many applications this removes the need for conventional rebar.

Surface preparation is minimal. A rough, uneven surface on the host structure is preferred over a smooth one, because it improves the bond between the host, the new grout and the panel. Panel edges overlap by 4 in. and are sealed in the field to make a watertight joint.

SPiRe®+ builds on the original SPiRe® (Sheet Pile Repair) system launched in 2018, which was designed mainly as a stay-in-place form. The T profiles add structural capacity, and the panel connections were improved. The original SPiRe® is covered by U.S. Patent 10,968,631, and SPiRe®+ is patent-pending.

  • Pultruded glass fiber and vinyl ester resin
  • Grit-coated T profiles bond and interlock with grout
  • Non-corroding: no steel in the panel
  • Light enough for a two-person crew, no cranes
  • No cofferdam required
  • No welding on site
Two SPiRe®+ panels side by side, one showing the T profiles and the other the flat face

INSTALLATION

How a Seawall Is Repaired with SPiRe®+

Where corrosion is concentrated in the splash zone, only that band is repaired. The panels extend a couple of feet above and below the corroded region. Typical design details and grout specifications are available for your engineer.

  1. Anchor

    L-bolts are anchored to the seawall on an approximate 3 ft x 3 ft (1 m x 1 m) grid. Panels are connected to the bolts and set at the required stand-off from the wall.

  2. Seal the joints

    Overlapping panel edges are sealed with a rubber butyl sealant to make them watertight, until the full repair length and height is covered.

  3. Close the space

    The bottom and sides of the annular space are sealed, for example with FRP or plywood plates cut to the wall profile and held up by eyebolts.

  4. Grout

    Epoxy grout seals the bottom, cementitious grout fills the bulk of the space (the tremie method can be used), and epoxy grout seals the top.

SPiRe®+ Panel at a Glance

MATERIAL
Pultruded glass fiber and vinyl ester resin
WIDTH
3 ft (914 mm)
LENGTHS
6 to 20 ft (1.84 to 6.10 m) in 2 ft increments; longer on special order; cut to length in the field
WALL THICKNESS
0.20 in. (5 mm)
REBAR EQUIVALENCY
No. 6 Gr. 60 @ 3.5 in. o.c.
WEIGHT
3.57 lb/ft² (17.42 kg/m²)
PROFILE
Flat outside face, protruding T profiles inside
BOND SURFACE
Grit-coated inside face
JOINTS
4 in. overlap, sealed in the field
ANNULAR SPACE
2 in. (50 mm) or larger
FILL
Cementitious or epoxy grout, or concrete
DATA SHEET
SPiRe®+ Panel PDS, June 2026 (see Product Data Sheets)

SPIRE® VS. SPIRE®+

How SPiRe®+ Differs from the Original SPiRe® Panel

The original SPiRe® panel remains in the Product Data Sheet library, and QuakeWrap® still points projects focused only on steel sheet pile repair to it.

Original SPiRe® panel and SPiRe®+ panel compared
SPiRe® (original) SPiRe®+
Construction Fiberglass fabrics, a structural core and vinyl ester resin, made by infusion Glass fibers and vinyl ester resin, made by pultrusion
Width 4 ft 3 ft (914 mm)
Length Up to 19 ft 6 to 20 ft in 2 ft increments, longer on special order
Thickness 0.375 to 0.5 in. 0.20 in. (5 mm) wall, plus T profiles
Built-in reinforcement No. Designed mainly as a stay-in-place form Yes. The flat panel and T profiles act as reinforcement
Published strength Flexural strength 23,900 psi, flexural modulus 1.81 x 10⁶ psi (ASTM D790) Flexure test equal to No. 6 Grade 60 bars at 3.5 in. in a 4 in. thick beam
Typical uses Corrosion protection and stay-in-place form for seawalls, sheet piles and bulkheads Seawalls, beams, decks, slabs, retaining walls and seawall extensions

Not sure which panel fits?

Send us the structure, its condition and the water levels. Our team will recommend the right QuakeWrap® system and provide specifications for your engineer.

GET A SEAWALL REPAIR CONSULTATION

FLEXURE TESTS

Beams Reinforced Only by SPiRe®+ Panels

QuakeWrap® tested three grout beams in which a SPiRe®+ panel formed the bottom of the section and was the only reinforcement, with no rebar in the tension zone. The beams were 10 ft (3.05 m) long, 8 in. (200 mm) wide and 2, 3 or 4 in. (50, 75 or 100 mm) thick. The T profiles faced up into Quikrete non-shrink precision grout with a specified strength over 6,000 psi (41 MPa).

The 3 and 4 in. beams were loaded at two points on a 9 ft (2.74 m) simple span. The 2 in. beam, sized for new flat roofs, was first loaded on a 4 ft (1.22 m) span to match typical roof joist spacing, where it proved very rigid, and then loaded to failure on a 6 ft (1.83 m) span.

Load and deflection stayed linear up to failure, and no beam failed by tension failure of the panel. Many fine cracks spread along each beam, showing a good bond between the grit-coated panel and the grout. The 4 in. beam reached 9,190 lb (41 kN), a moment of 220.5 kip-in. (24.9 kN-m).

To carry the same moment with steel, the 4 in. beam would need No. 6 Grade 60 bars at 3.5 in. (20 mm, 500 MPa bars at 120 mm). The paper notes that this equivalence applies to the tested geometry, span, loading and materials, so capacity is checked for each project. The June 2026 SPiRe®+ data sheet rates the panel the same way. (The December 2025 sheet listed No. 5 bars at 2.5 in., about the same steel area, roughly 1.5 sq in. per foot.)

2 in. beam
221.8 kip-in./ft
3 in. beam
306 kip-in./ft
4 in. beam
330.7 kip-in./ft
Steel equivalent
No. 6 Gr. 60 @ 3.5 in.
Grout beam cast on a SPiRe®+ panel in the test frame, with the panel's T profiles visible at the end

TEST DATA

SPiRe®+ Flexural Test Results by Beam Thickness

Strength and measured stiffness (EI) of the three test beams, from Prof. Ehsani's paper for the SMSB 2026 bridge conference in Vancouver. The EI values help engineers plan seawall, slab and roof applications.

Dimensions and flexural strength of SPiRe®+ test beams (Ehsani, SMSB 2026, Table 1)
2 in. beam (S2) 3 in. beam (S3) 4 in. beam (S4)
Test span 6 ft (1.83 m); stiffness check on 4 ft (1.22 m) 9 ft (2.74 m) 9 ft (2.74 m)
Flexural strength 147.9 kip-in. (16.7 kN-m) 204 kip-in. (23 kN-m) 220.5 kip-in. (24.9 kN-m)
Per foot of panel width 221.8 kip-in./ft (83.5 kN-m/m) 306 kip-in./ft (115 kN-m/m) 330.7 kip-in./ft (124.5 kN-m/m)
Measured EI 218 kip-ft² (90 kN-m²); 225 kip-ft² (93 kN-m²) on the 4 ft span 627 kip-ft² (259 kN-m²) 1,126 kip-ft² (465 kN-m²)
Potential use Flat roofs and slabs Seawall repair Varies

IN SERVICE

Where SPiRe®+ Has Been Used Since Its Launch

In the two years since its introduction, SPiRe®+ has been used to repair timber, concrete and steel seawalls and bulkheads, strengthen bridge decks, girders and pier walls, extend seawalls against sea-level rise, and build fire- and water-resistant roofs and floors.

On corroded concrete waterfront walls in Florida the panels also wrapped a pilaster. Panel edges are joined with 4 in. x 4 in. (100 x 100 mm) angles, so the form can follow almost any shape. Anchor bolts pass through GFRP washers, and the nuts are covered with epoxy-filled plastic caps to protect them from corrosion.

At Dickinson, North Dakota, 3 ft x 9 ft (0.91 x 2.74 m) panels with 4 in. (100 mm) sealed overlaps were bolted to an eroded bridge pier wall with a 2.5 in. (63 mm) gap and filled with flowable non-shrink grout; the paper reports the contractor finished in two days. On a corroded prestressed slab in coastal North Carolina, panels went on the underside and grout was injected through holes drilled from above, leaving a smooth finished surface.

  • Corroded steel sheet pile seawall, New York
  • Concrete seawalls and a pilaster, Florida
  • Bridge pier wall, North Dakota
  • Prestressed concrete slab, North Carolina
  • Bridge girders, installed at night to limit traffic disruption
Workers bolting gray SPiRe®+ FRP panels around a corroded concrete seawall and pilaster in Florida, with angle connectors and capped anchor bolts marked

Advantages of SPiRe®+

  • No cofferdams

    Panels install underwater, so marine repairs skip dewatering.

  • Virtually no surface prep

    No patching or grinding. A rough surface bonds better.

  • Three products in one

    Formwork, reinforcement and waterproofing.

  • Nothing to corrode

    The panels and T profiles contain no steel.

  • Impervious barrier

    Keeps moisture, oxygen and chemicals away from the host structure.

  • Light to handle

    A two-person crew can place panels without cranes.

  • Fewer field errors

    The reinforcement is built into the panel.

  • Fast

    Beam and slab repairs in hours; a bridge beam in one night.

CHOOSE YOUR SYSTEM

Wet Layup vs. SPiRe®+ at a Glance

The right system depends on the member's condition and its environment. Wet layup FRP fits dry, accessible members with a sound, prepared surface. SPiRe®+ fits wet or submerged members and members with heavy deterioration, where surface preparation is difficult.

Wet Layup FRP SPiRe®+ Panels
Environment Dry, accessible structures Wet, splash zone or underwater
Surface preparation Patched, ground and dry Minimal; rough surfaces bond better
What it does Adds flexural, shear and confinement capacity Formwork, reinforcement and waterproofing in one
Material Carbon or glass fabric, about 0.04 to 0.08 in. per ply Pultruded glass FRP panels, 3 ft wide, grout-filled
Best fit AASHTO girders, T-beams, complex shapes Badly deteriorated members that need a new shell

Not sure which system fits?

Tell us about the member and conditions. Our team will recommend the right QuakeWrap® system.

GET A SEAWALL REPAIR CONSULTATION

PROVEN RESULTS

SPiRe® and SPiRe®+ Projects

Early SPiRe®+ installations range from a submarine repair facility to a timber bulkhead in New York.

TIMBER BULKHEAD

SPiRe®+ Repairs a Timber Bulkhead in Queens, New York

At Anable Basin in Queens, 3 ft wide SPiRe®+ panels were anchored in front of a deteriorated timber bulkhead to form a continuous impervious form, and the space between the panels and the wall was filled with cementitious grout. The repairs can be done under water without cofferdams.

Plays from YouTube

SPiRe®+ FAQs

Can SPiRe®+ be installed underwater?

Yes. The panels are installed underwater without cofferdams, which saves time and cost on most marine repairs.

How does SPiRe®+ repair a seawall?

Panels are anchored in front of the wall on L-bolts, the overlapping joints are sealed, and the space between panel and wall is filled with grout. The result is a new watertight structural face that stops further soil loss and keeps oxygen and moisture off the old wall.

What if the steel sheet pile is too corroded to anchor to?

New steel H-piles can be driven a few inches in front of the seawall and the panels placed horizontally, spanning between the existing or new piles. The new system can be designed to resist all or part of the soil pressure. The H-piles need their own corrosion protection; the panels do not corrode.

Can SPiRe®+ be used for new construction?

Yes. For a new retaining wall, two rows of panels connected by through-bolts are set on a conventional footing with starter bars extending about 2 ft (600 mm), braced, and filled with concrete. The wall must be at least 4 in. (100 mm) thick. The panels serve as formwork, reinforcement and waterproofing.

How is SPiRe®+ different from PileMedic®?

SPiRe®+ is a rigid stay-in-place panel for walls, beams and slabs. PileMedic® laminates wrap individual piles and columns as a jacket that is filled with grout.

What should the engineer check when designing with SPiRe®+?

The connection to the host structure, the bond with the grout or concrete fill, long-term behavior under sustained and cyclic load, temperature changes, impact and exposure, and installation quality, especially grout placement and anchorage details. The rebar equivalence is a design reference; capacity is checked for each project's geometry, loads and service conditions.

Can SPiRe®+ raise the crest of an earth dam?

That is a proposed application, not yet built on a dam. Panels set in a narrow trench along the crest and backed with 3 to 4 in. of concrete would form a thin wall that raises the crest to prevent overtopping. Final height, embedment and details come from project-specific engineering.

Can you provide specifications and sample design details?

Yes. Our team will recommend the right SPiRe®+ system and provide typical design details, grout specifications and product data for your engineer of record. Design calculations must be made and certified by a licensed professional engineer.

U.S. military crew training on SPiRe seawall repair

Have a Seawall That Needs Repair?

Tell us about the seawall and site conditions. Our team will recommend the right SPiRe®+ system and provide specifications for your engineer.