BUILDINGS & BRIDGES

FRP Slab Strengthening and Deck Repair

Carbon or glass FRP bonded to a concrete slab or deck adds flexural capacity for new loads, restores capacity lost to corroded reinforcing steel and adds punching shear capacity around columns, at about 0.05 in. thick. SPiRe®+ panels form a new shell around corroded slabs and marine decks.

  • More live load capacity
  • About 0.05 in. thick, no lost headroom
  • Floor slabs, roofs & marine decks
Custom SPiRe shell for corroded marine deck repair at Port of Galveston

WHY SLABS NEED STRENGTHENING

Why Slabs and Decks Need Strengthening

Most slab projects on the old QuakeWrap® pages started with one of these problems.

  1. New, heavier loads

    Equipment, high-density filing systems, a rooftop pool or a new floor added on top can exceed the capacity the slab was built for.

  2. Corroded reinforcing steel

    As the rebar corrodes, the slab loses tension capacity. FRP can be designed to restore the original capacity.

  3. Excessive deflection and sag

    Design or construction errors can leave a slab that deflects and sags under service loads.

  4. New openings and punching shear

    Cutting an opening for a stairway overstresses the slab around it, and added loads can leave too little punching shear capacity at columns.

HOW IT WORKS

How FRP Strengthens a Slab

A slab resists bending through a couple: compression on one face and tension on the other. FRP bonded to the tension face increases the tension force, and so the moment capacity. In most cases the slab already has enough compressive strength. If needed, FRP can also be added to the compression face.

Depending on access, the FRP goes on the top or the bottom of the slab. Top-side work keeps the floor below in service and avoids congested ceilings full of pipes and conduits. Covering a fraction of the slab surface with FRP may be enough to strengthen the whole slab.

The thin sheets, about 0.05 in. (1.3 mm) thick, are applied like wallpaper, cure within a day and reach two to three times the tensile strength of steel. The bond matters: pioneering studies by QuakeWrap's principals in the late 1980s showed that improper epoxies can produce retrofits that add little strength, and that work led to QuakeBond™ epoxies.

  • Positive and negative moment regions
  • Punching shear capacity around columns
  • Reinforcement around new openings
  • Our team provides specifications for your engineer
typical FRP thickness (1.3 mm)
0.05 in.
typical cure time
1 day
the tensile strength of steel once cured
2 to 3×

ADVANTAGES

Advantages of FRP for Slab Strengthening

  • More flexural strength

    In both positive and negative moment regions.

  • Stiffer slab

    Reduced deflection at service loads.

  • Narrower cracks

    Reduced crack widths for better durability.

  • Partial coverage

    Covering a fraction of the slab may strengthen the whole slab.

  • Hidden under flooring

    At about 0.05 in. thick, FRP fits under floor coverings.

  • Waterproofing

    The FRP can also serve as a waterproofing membrane.

  • No lost headroom

    No reduction in overhead clearance, for example in parking garages.

  • Lower cost

    Lower cost than strengthening with conventional methods.

Adding load to a slab?

Tell us about the slab, the new loads and which side you can reach. Our team will recommend the right QuakeWrap® system and provide specifications for your engineer.

GET A SLAB & DECK REPAIR CONSULTATION

CASE STUDY

Flattening a Sagging Slab: Five-Story Building, Westwood, California

The first-floor slab of this building had deflected excessively and needed to be strengthened and flattened. New concrete or steel beams below the slab were ruled out because they would have cut the overhead clearance in the parking garage underneath.

The slab was temporarily shored while selected areas on its bottom and top surfaces were reinforced with glass fabric FRP. After the epoxy cured, the shoring was removed and the floor was leveled with a lightweight leveling grout. The tension in the FRP kept the slab flat after the shoring came out, similar to post-tensioning.

None of the many pipes hung from the slab had to be removed, and the headroom in the parking area was hardly reduced.

  • Glass FRP on the top and bottom faces
  • Shored, strengthened, then leveled
  • Pipes left in place, headroom kept
Five-story building in Westwood, California, whose sagging first floor slab was strengthened and flattened with glass FRP

MARINE DECKS

Custom SPiRe® Shells for Corroded Piers and Decks

Where there is little headroom above the water, a rigid FRP shell is built to the exact geometry of the deck beams. After the deteriorated concrete is removed, the shell is lifted into place and attached to the underside of the deck, and the space between shell and structure is filled with concrete, grout or epoxy grout. The shell stays in place as an impervious form (U.S. Patent 10,968,631).

Plays from YouTube

PROVEN RESULTS

Slabs & Decks Projects

From marine decks to hospital floors. Each project sheet gives the problem, the solution and the quantities.

More slab projects

Providence Hospital (Anchorage), an MRI floor in Tucson, the LA Museum of Natural History roof slabs and a fire-damaged TEP power station platform. Tell us about your slab and we will share the closest match.

GET A SLAB & DECK REPAIR CONSULTATION

Slabs & Decks FAQs

Should I use carbon or glass FRP?

Carbon has the highest strength and stiffness and is common for flexural and shear strengthening of beams, slabs and girders. Glass costs less, is non-conductive and is common for column confinement, masonry walls, blast and seismic retrofit.

Can you provide specifications and design details for our engineer?

Yes. Our team will recommend the right QuakeWrap® system and provide product data sheets, specifications and sample design details for your engineer of record.

Can a slab be strengthened from the top?

Yes. FRP can go on the top or bottom surface, depending on access. Top-side strengthening let a hospital in Anchorage and a medical center in Tucson stay in operation, with the rooms below in use.

Will FRP reduce headroom or show under the floor finish?

No. The FRP is about 0.05 in. (1.3 mm) thick, so it causes no real loss of overhead clearance and can be hidden under floor coverings.

Can FRP add punching shear capacity around columns?

Yes. At Georgian Towers in Silver Spring, Maryland, FRP anchors were installed through holes drilled around 12 columns and bonded to carbon strips on top of the slab.

We need to cut an opening in a slab. Can FRP help?

Yes. Carbon FRP strips around the opening make up for the strength lost to the cut. At Holy Cross Hospital the strips were applied before cutting to limit deflection, and the work took one day.

Can SPiRe®+ repair corroded slabs and decks?

Yes. SPiRe®+ panels act as formwork, reinforcement and a waterproof barrier for corroded slabs and decks, including prestressed planks at a coastal resort and slabs in hard-to-reach industrial areas.

Crew applying FRP to the underside of a concrete beam

Have a Project That Needs Repair?

Tell us about your structure. Our team will recommend the right QuakeWrap® system and provide specifications for your engineer.