FRP Test Results & Approvals

Listings, code evaluation reports and independent test reports for QuakeWrap® systems: NSF/ANSI 61 for drinking water, IAPMO UES ER-828, the ICC-ES record, and studies by the U.S. Army Corps of Engineers, state DOTs, GTI, TRI and TTC. Each entry shows its dates, scope and source document.

  • NSF/ANSI 61
  • IAPMO UES ER-828
  • ICC-ES
  • ARMY CORPS
  • DOT STUDIES
PipeMedic wet layup FRP being applied to a pipe
ER-828 IAPMO UES report, valid through 10/31/2026
IAPMO R&T listing file N-11990
NSF/ANSI 61
IAPMO UES code evaluation report
ER-828
test program, University of Miami
AC125
steel H-piles tested for Texas DOT
14

AT A GLANCE

Listings and Code Evaluations

Dates come from the documents on file. Status is what we could verify on October 20, 2026. Always check the issuer's directory before you rely on a listing.

QuakeWrap listings and evaluation reports with dates and status
Listing or report Issued by Scope Dates on file Status Document
NSF/ANSI/CAN 61, file N-11990 IAPMO R&T Drinking water contact: QuakeWrap® fabrics with QuakeBond™ 300SR as tank coatings and StifPipe® on new pipe Listing current as of May 12, 2026, to NSF/ANSI/CAN 61-2023 (2023 certificate void after January 2025) Active in the IAPMO R&T directory, checked 10/20/2026 Current listing (PDF)
Evaluation Report ER-828 IAPMO Uniform Evaluation Service QuakeWrap® FRP systems for strengthening concrete under the IBC and IRC, with potable water contact under the UPC and IPC Issued 10/18/2022, revised 12/23/2025, valid through 10/31/2026 Listed as valid and active, checked 10/21/2026 [Confirm renewal: check that IAPMO UES reissues ER-828 after it expires on 10/31/2026] ER-828 (PDF)
Evaluation Report ESR-3605 ICC-ES QuakeWrap® FRP systems under the 2021, 2018 and 2015 IBC, per QuakeWrap's legacy page Issued February 2021 Not in the ICC-ES report directory on 10/20/2026, so not a current report Ask about ESR-3605
Test report R-5.10_QUA_13-09-10 University of Miami Structures and Materials Laboratory Qualification tests per ICC-ES AC125 for U20C, U41C and B20C with 300SR October 4, 2018 Test report, not a listing Test report (PDF)

DRINKING WATER

NSF/ANSI 61 Listing for Drinking Water

IAPMO R&T lists QuakeWrap® fabrics U18C, U20C, U27C, U41C, B20C, U27G and B26G, saturated with QuakeBond™ 300SR, to NSF/ANSI/CAN 61-2023 under file N-11990. The listing covers tank coatings and StifPipe® on new pipes for cold water. The listing on file is current as of May 12, 2026, and the IAPMO R&T directory showed it as active on October 20, 2026.

The listing calls for a 72-hour cure at ambient temperature after the last layer, a 1-hour flush at 10 gallons per minute before use, and a maximum total dry film thickness of 90 mils. It accepts immediate return to service in pipe 6 in. and larger and tanks of 3,000 gallons and larger. [Confirm with QuakeWrap or IAPMO R&T which minimum sizes apply: ER-828 says 8 inches (152 mm), older pipemedic.com pages say 8 in., and the May 2026 listing's tank line still reads 3,000 gallons or less]

IAPMO UES ER-828 separately recognizes 300SR over carbon fabrics B20C, U20C, U27C and U41C for potable water contact under the Uniform Plumbing Code and International Plumbing Code, based on NSF 61 Section 5 testing.

  • Seven QuakeWrap® fabrics with QuakeBond™ 300SR
  • 72-hour cure, 1-hour flush before service
  • Verify the listing before you specify
Water storage tanks repaired with FRP

CODE EVALUATION

IAPMO UES ER-828, AC125 and AC178

ER-828 recognizes QuakeWrap® carbon fabrics B20C, U20C, U27C and U41C and glass fabrics B26G and U27G with 300SR for strengthening columns, beams, slabs and walls. Design follows IBC Chapter 19 (ACI 318) and the QuakeWrap Design Manual. The FRP is not relied on for compression, needs 72 hours at 70°F before loading, and requires special inspection per AC178. Test data follow AC125. Fire-resistance-rated construction is outside its scope.

QUAKEWRAP® WET & DRY LAYUP

PILEMEDIC® STRUCTURAL TESTS

PileMedic® Tests by the Army Corps and State DOTs

Agency-funded research on piles and columns repaired with PileMedic®. Some studies compared several commercial systems. Results apply to the specimens tested.

PileMedic test programs with sponsor, specimens, finding and report
Program Sponsor and lab Specimens What it found Report
PIER JCTD Spiral 1, February 2017 U.S. Army Corps of Engineers, ERDC Commercial pile jackets for expedient port repair Market research and testing of commercial jackets led to one jacket, packaged in modular kits that fit on C-17 aircraft. The Spiral 1 demonstration ran at ERDC in Vicksburg, Mississippi, in October 2016, with a field assessment at Joint Base Pearl Harbor-Hickam in February 2017. Neither the fact sheet nor the Army's account names the product. [Confirm with QuakeWrap: supply a USACE or ERDC document that names PileMedic® as the selected jacket, or keep this row product-neutral] PIER fact sheet (PDF)
Report 0-6731-1, Dec. 2015 (published April 2017) Texas DOT and FHWA; University of Houston and Texas Tech 14 corroded HP12x53 steel H-piles, two groups of seven, two FRP jacket systems patented by Prof. Ehsani Axial capacity restored to the nominal uncorroded value in all but one pile, which was built without the anchors its design called for Final report (PDF, about 131 MB)
Timber pile rehabilitation, final report SPTC15.1-43-F, June 2017 Southern Plains Transportation Center (U.S. DOT University Transportation Centers Program); research by Louisiana Tech University 42 tests on undamaged, damaged and repaired Louisiana-type timber piles; Denso, Simpson Strong-Tie and PileMedic® repairs Repaired piles were tested under concentric and eccentric loads with FRP jackets and epoxy or grout fill Final report (PDF)
Timber piles for retrofit and rating, April 2014 Nebraska Department of Roads; Florida International University Five full-scale timber piles with 1 to 2 in. deep hourglass damage, PileMedic® glass laminates Failure loads of 5.3 to 9.9 times the design capacity Draft final report (PDF)
Emergency repair of an earthquake-damaged column, 2015 Caltrans and the National University Transportation Center at Missouri S&T Oval 24 in. x 36 in. RC bridge column with buckled and fractured bars, prefabricated thin CFRP laminate jacket Repair restored the column's lateral strength and deformation capacity under cyclic load Composite Structures paper (PDF)
Utility pole field test, 2014 Tucson Electric Power, with QuakeWrap Class III 45 ft wood distribution pole, broken, then strengthened with carbon strips, a PileMedic® wrap and injected resin from 2 ft 9 in. below ground to 25 ft 9 in. above The pole first broke at about 1,070 lb. After strengthening it broke at 2,400 lb (2¼ times the original load), exactly where the repair stopped. Retested on March 12, 2014 with the load 24 ft above ground, it failed at 3,200 lb at the bottom end of the jacket. QuakeWrap test summary (PDF)

U.S. ARMY CORPS OF ENGINEERS

PileMedic® Makes Military Grade Pier Repairs

Plays from YouTube

PIPEMEDIC® TESTS

Pipe Tests: GTI, TRI, TTC and PERTAMINA

Independent and partner tests on StifPipe®, InfinitPipe®, SuperLaminate™ and externally wrapped steel pipe. Where a report file is missing from the old sites, ask us for a copy.

PipeMedic test programs with lab, specimens, finding and report
Test Lab and client Specimens What it found Report
GTI Project 21068 Gas Technology Institute for PSE&G PipeMedic® laminates bridging a 24 in. free span in 6, 12 and 16 in. steel gas pipe No leakage at 250 psig, about four times the 60 psig operating pressure, meeting the ASTM F2207 test of at least twice MAOP for one hour GTI report (PDF)
Deflection test Texas Research Institute (TRI) 46 in. diameter StifPipe® sample Load-deflection response suitable for slip-lining. [Confirm with QuakeWrap: supply the TRI report and test date. pipemedic.com shows only the test photo and load-deflection curve] Request the data
Experimental evaluation, July 2014 Trenchless Technology Center, Louisiana Tech, for QuakeWrap InfinitPipe®: ASTM D2412, D2444, D1598, D638, D790 and D2240 tests Performed well under mechanical and impact loads and under simulated 25 ft of overburden; recommended an impervious inner layer and long-term tests TTC report (PDF)
External repair of corroded steel pipe PERTAMINA Technical Services; Polymer Technology Center, Indonesia 5 in. steel pipe, 3 mm wall, 20 mm hole, glass and carbon fabric with QuakeBond™ J333SR underwater resin Held to 93.1 bar (1,351 psi), then a small leak at the hole. QuakeWrap's summary says PERTAMINA approved the system in 2013, and pipemedic.com shows PERTAMINA field repairs of oil and gas pipes in water. [Confirm with QuakeWrap: supply the PERTAMINA approval document, or drop the word approval] Test report (PDF)
Pressure test of PipeMedic® laminate QuakeWrap test at Link-Pipe, Richmond Hill, Ontario 0.026 in. carbon-glass laminate formed into an unsupported 11¼ in. cylinder Failed at 240 psi by axial tension in the glass fibers, with no backing from a host pipe Test report (PDF)
Parallel-plate tests (ASTM D2412) University of Arizona, Dept. of Mining and Geological Engineering StifPipe® External load tests for gravity pipes, per pipemedic.com. [Confirm with QuakeWrap: supply the University of Arizona test report, date and results; no QuakeWrap site posts them] Request the data

Specifying a pipe repair?

Tell us the pipe size, material and operating pressure. We will send the test reports and specifications your engineer needs.

REQUEST SPECIFICATIONS & DESIGN DETAILS

READ IT RIGHT

Listed, Evaluated or Tested: What Each Means

These documents carry different weight with a building official or owner. Specify to the one your project needs.

  • Listed

    A certification body, here IAPMO R&T, lists the product to a standard such as NSF/ANSI 61 and audits production. Check the directory for current status.

  • Evaluated

    An evaluation service, here IAPMO UES, reviews test data against acceptance criteria and confirms code compliance for the uses and limits in the report.

  • Tested

    A lab or agency study reports results for the specimens tested. It supports design decisions but is not a product approval.

Need the full reports for a submittal?

Tell us which documents your engineer or owner needs and we will send them.

REQUEST SPECIFICATIONS & DESIGN DETAILS

Test and Approval Questions

Is QuakeWrap® FRP listed for drinking water?

Yes. QuakeWrap® fabrics with QuakeBond™ 300SR are listed by IAPMO R&T to NSF/ANSI/CAN 61-2023 under file N-11990. The IAPMO R&T directory showed the listing as active on October 20, 2026. Check the directory again before you specify.

Is IAPMO UES ER-828 current?

Yes, as of October 21, 2026. The IAPMO UES directory lists ER-828 as valid and active. The current revision is dated December 23, 2025 and is valid through October 31, 2026. [Confirm renewal: check that IAPMO UES has reissued ER-828 after October 31, 2026]

Does QuakeWrap® have an ICC-ES report?

QuakeWrap's legacy site listed ICC-ES ESR-3605, issued February 2021. It is not in the ICC-ES report directory as of October 20, 2026, so it should not be cited as a current report. The current code evaluation is IAPMO UES ER-828, based on test data per acceptance criterion AC125.

What did the Army Corps of Engineers test?

The U.S. Army Engineer Research and Development Center's PIER program researched and tested commercial pile jackets for rapid port repair, chose one technology and packaged it in modular kits that fit on C-17 aircraft. QuakeWrap's PileMedic® user manual was prepared for the Corps. The Army's public documents do not name the selected product. [Confirm with QuakeWrap: supply a USACE or ERDC document that names PileMedic®]

Do test results mean the product is certified?

No. A test report shows how the specimens performed. A listing or evaluation report is a separate approval with its own scope and dates. This page labels each one.

Can I get a report that isn't linked here?

Yes. The GTI and PERTAMINA pipe reports are now linked above. For tests without a posted report, such as the TRI deflection test and the University of Arizona StifPipe® tests, ask and we will send what is on file with your specification package.

Frame from a 2010 QuakeWrap demonstration of SuperLaminate bridging a gap in a steel pipe

Need Test Reports for a Submittal?

Tell us what your engineer or owner needs. Our team will recommend the right QuakeWrap® system and provide the specifications and reports for your engineer.