6840 S. Tucson Blvd, Tucson, AZ 85756, U.S.A.
GET A CONSULTATION

FOR ENGINEERS

FRP Repair Specifications & Sample Design Details

Guide specifications and typical design details for QuakeWrap® products, ready for your engineer of record to edit, adapt and issue. Specifications come in PDF and Word.

  • Editable specifications in PDF and Word
  • Typical details for piles, seawalls, beams and walls
  • Warranty terms for each product line
Concrete beam repaired with SPiRe+ stay-in-place panels
PDF + Word editable guide specifications
guide and installation specifications
4
sample design detail sets
9
SPiRe®+ panel system section
03 10 00.01
cementitious and epoxy grout section
03 30 12

FROM THE PILEMEDIC® SPECIFICATION

Nominal PileMedic® Jacket Values

Nominal confining pressure and longitudinal steel equivalent for a 2-ply PileMedic® jacket, from the generic specification dated December 1, 2015. Steel equivalent is Grade 60 bars spaced around the pile perimeter. Check values against the current product data sheet before design.

Nominal values for a 2-ply PileMedic jacket by pile diameter
Pile diameter Glass: confining pressure Glass: steel equivalent Carbon: confining pressure Carbon: steel equivalent
10 in. 645 psi #4 at 3 in. 1,050 psi #4 at 3 in.
12 in. 535 psi #4 at 3 in. 875 psi #4 at 3 in.
15 in. 430 psi #4 at 3 in. 700 psi #4 at 3 in.
18 in. 355 psi #6 at 7 in. 580 psi #6 at 7 in.
24 in. 265 psi #6 at 7 in. 435 psi #6 at 7 in.
36 in. 180 psi #8 at 11 in. 290 psi #8 at 11 in.
48 in. 130 psi #8 at 11 in. 220 psi #8 at 11 in.
60 in. 107 psi #8 at 11 in. 175 psi #8 at 11 in.

FILL MATERIAL

Choosing the Fill for a PileMedic® Jacket

The generic specification offers three fill options, chosen by the width of the annular space between the pile and the jacket and the condition of the pile.

PileMedic fill options by annular space
Fill Annular space When to use it Structural note
QuakeBond™ 320LV low-viscosity resin Under ¼ in. Circular piles that are cracked or decayed, so resin fills the voids Bonds the jacket and added bars to the pile for flexure
PileMedic® UW epoxy grout ¼ in. to 1 in. Wider annulus; about 180 to 225 lb of silica per 5 gal of epoxy Same structural benefit as low-viscosity resin
PileMedic® UW underwater grout Over 1.5 in. Large annular space Bond to the jacket is conservatively ignored for flexure

Not sure which fill or detail fits?

Send the pile size, material and damage. Our team will recommend the right QuakeWrap® system and provide specifications for your engineer.

REQUEST SPECIFICATIONS & DESIGN DETAILS

GROUT AND FORMS

Grout & Form-A-Tube® Specifications

The grout section covers concrete and grout placed with QuakeWrap® systems, including PileMedic®, SPiRe® and StifPipe®. The Form-A-Tube® installation specification covers the reusable PVC form for pile encapsulation.

ABOUT FORM-A-TUBE®

[Content needed] PipeMedic® and QuakeWrap® fabric specifications

No published guide specification exists for StifPipe®, SuperLaminate™, InfinitPipe®, PipeMedic® wet layup pipe lining or QuakeWrap® wet and dry layup fabrics. None is in the quakewrap.com, pilemedic.com or pipemedic.com media libraries (checked 10/21/2026) or in Wayback captures of the three sites. In 2009 pipemedic.com listed a "PipeMedic™ specifications" Word and PDF file, but neither was archived and both links are dead. QuakeWrap must supply these specifications, or confirm they stay available on request. QuakeWrap must also confirm whether the Installation Instructions QW/II-2020, Quality Control Plan QW_QCP and Design Manual Version 1.0_1 cited in IAPMO UES ER-828 can be shared with engineers.

SUBMITTALS

What the PileMedic® Specification Asks the Contractor to Submit

A preview of the submittal section, so your engineer knows what to expect. Edit it to suit the project.

  • Product data

    Data sheets for the FRP laminate, fill resin, adhesive resin and accessories, plus safety data sheets.

  • Design and shop drawings

    Confining pressure calculations, details per local codes, and shop drawings showing installation steps, spacer sizes, overlaps and fill, sealed by a professional civil engineer.

  • Certifications

    An ASTM F2207 test report for confining pressure, full-scale test summaries, and material certifications showing laminate fabrication and resin manufacture dates.

  • Quality records

    Daily installation reports with air and water temperatures and the lot numbers of laminates and resins used on each pile.

Need a project-specific specification?

Tell us about the structure and we will send the specifications and details your engineer needs.

REQUEST SPECIFICATIONS & DESIGN DETAILS

WARRANTY

What the Product Warranties Cover

SPiRe®+ panel system: the specification calls for a two-year material warranty against defects. Extended material warranties may be available from the manufacturer for an added fee and may require periodic site inspection or maintenance. The contractor provides a one-year warranty on installation labor. Cosmetic defects, impact damage and loads well above normal operation are excluded, and repairs or changes to the products by others void the warranty.

QuakeWrap® fabrics, QuakeBond™ resins, PileMedic® laminates, StifPipe® and SPiRe®+ panels: each current product data sheet carries the same warranty. QuakeWrap, Inc. warrants the product for one year from the date of installation to be free from manufacturing defects and to meet the properties on the current data sheet, when used as directed within its shelf life. The user decides whether the product suits the intended use. The remedy is limited to the purchase price or replacement of the product, not labor. [Confirm with QuakeWrap: the SPiRe®+ specification (v1, 11/23) calls for a two-year material warranty, while the June 2026 SPiRe®+ data sheet states one year. Say which governs.]

  • Data sheets: one-year product warranty
  • SPiRe®+ specification: two-year material warranty
  • Contractor: one-year labor warranty
Crew repairing a corroded seawall with FRP panels

Specification Questions

Can I edit the specifications?

Yes. The PileMedic® and SPiRe®+ specifications come in MS Word. The generic PileMedic® specification is written in a non-proprietary format: delete the sections that do not apply and keep the one option you plan to use.

Are the sample design details ready for construction?

No. They are typical details marked Not for Construction, with the Designed and Approved By block left blank. Your engineer of record adapts layers, overlaps, reinforcement and terminations to the project.

Which specification covers the grout inside a jacket?

Section 03 30 12 covers cementitious grout, epoxy grout and cellular concrete placed with PileMedic®, SPiRe® and StifPipe® systems and other FRP jackets. The PileMedic® specification explains when to use low-viscosity resin, epoxy grout or underwater grout.

What if I don't see a specification for my product?

Ask for it. Our team will recommend the right QuakeWrap® system and send the specifications and details your engineer needs.

What warranty comes with QuakeWrap® products?

The SPiRe®+ specification calls for a two-year material warranty and a one-year contractor labor warranty. Ask for the current warranty terms for other products with your specification package.

Crew wrapping timber piles under a pier with PileMedic laminates

Need a Specification We Don't List?

Tell us about the structure. Our team will recommend the right QuakeWrap® system and provide specifications for your engineer.